Precision Pressure Sensors for HVAC Air Quality Systems

Monitor air filter status, maintain optimal indoor air quality, and reduce energy costs with Honeywell’s advanced pressure sensing solutions

Why Choose Honeywell for HVAC Applications?

Air Filter Monitoring

Detect clogged filters early with precise differential pressure measurement

Energy Efficiency

Optimize HVAC performance and reduce energy costs

Wide Media Compatibility

Supports corrosive fluids, refrigerants, and harsh environments

High Reliability

Up to 1.7 million hours MTTF for long-term operation

Featured Pressure Sensor Series

ABP2 Series

Cost Competitive

Low-pressure board mount sensors with I²C digital output, ideal for air filter monitoring and cleanroom applications.

  • Range: 2.5 mbar to 20 bar
  • Accuracy: As low as ±1.5% FSS total error band
  • Output: Analog or Digital (I²C/SPI) interface
  • Temperature: -20°C to 110°C compensated

HSC Series

High Accuracy

Industry-leading accuracy and stability for demanding HVAC pressure measurement and control applications.

  • Range: 1.25 mbar to 10 bar
  • Accuracy: As low as ±1% FSS total error band
  • Output: Analog or Digital (I²C/SPI) interface
  • Temperature: 0°C to 50°C compensated

MIP Series

Media-Isolated

Hermetically sealed stainless steel sensors for refrigerants, corrosive media, and harsh HVAC/R environments.

  • Range: 1 to 70 bar / 15 to 1000 psi
  • Accuracy: As low as ±0.75% FSS total error band
  • Output: Analog or Digital (I²C/SPI) interface
  • Media: Supports almost all media in harsh environments

Key HVAC Applications


Air Filter Monitoring

Monitor differential pressure across air filters to detect clogging early and maintain indoor air quality

Chiller & Refrigeration

Measure compressor pressure in refrigeration cycles to optimize energy efficiency

Cleanroom Pressure Control

Maintain precise differential pressure in cleanrooms and pharmaceutical facilities

Building Automation

Integrate with BMS for real-time monitoring and predictive maintenance

Frequently Asked Questions


ABP2 or HSC Series with appropriate pressure range. High resolution (14-bit) and low total error band accurately detect pressure changes between clean and clogged filters.

Yes, MIP Series is designed for refrigerants including R134A, R407C, R410A, R448A, R32, and R1234ze with media-isolated construction.

Board mount (ABP2, HSC) are for dry, non-corrosive gases with digital output. Media-isolated (MIP) use hermetic sealing for aggressive media like refrigerants.

Implement auto-zero calibration at system startup. Take a zero-pressure reading before starting the fan to eliminate sensor offset errors.

MTTF of 1.7 million hours (194 years) at 10-30°C. Long-term drift is 0.25-0.35% FSS per 1000 hours, eliminated via auto-zero.